BJMDD - TECHALLOY, 7018, 7018-A1

Product Identification

Product ID:TECHALLOY, 7018, 7018-A1
MSDS Date:09/01/1989
FSC:3439
NIIN:00-465-1914
MSDS Number: BJMDD

Responsible Party
TECHALLOY MARYLAND INC, REID-AVERY DIV
2310 CHESAPEAKE AVE
BALTIMORE, MD 21222
US

Emergency Phone: 301-633-9300; 800-638-1458

Info Phone: 301-633-9300

Cage: 59711

Contractor
TECHALLOY COMPANY, INC.
BALTIMORE, MD 21222 US

Telephone: 410-633-9300; 800-638-1458

Cage: 59711

Ingredients

IRON (LIMITS FOR IRON OXIDE AS FE)

CAS: 7439-89-6

RTECS: NO4565500

Fraction By Weight: 55-70%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3


MANGANESE (SARA III)

CAS: 7439-96-5

RTECS: OO9275000

Fraction By Weight: 0.5-2%

OSHA PEL (C) 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9293


SILICON

CAS: 7440-21-3

RTECS: VW0400000

Fraction By Weight: 0.1-1%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 0-3.5%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


MOLYBDENUM

CAS: 7439-98-7

RTECS: QA4680000

Fraction By Weight: 0-1%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3; 9293


CALCIUM CARBONATE (MARBLE) (LIMESTONE)

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: 5-12%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9192


CALCIUM FLUORIDE

CAS: 14542-23-5

Fraction By Weight: 3-10%

OSHA PEL 2.5 MG/M3 (AS F)

ACGIH TLV: 2.5 MG/M3 (AS F)


POTASSIUM TITANATE

CAS: 12030-97-6

Fraction By Weight: 0-2%

ACGIH TLV: 10 MG/M3 (MFR)


POTASSIUM ALUMINUM SILICATE (FELDSPAR)

CAS: 68476-25-5

Fraction By Weight: 0-2%

ACGIH TLV: 2 MG/M3 (NOC)


ALPHA-ALUMINA (ALUMINUM OXIDE) (EPA LISTS ONLY FIBROUS

CAS: 1344-28-1

RTECS: BD1200000

Fraction By Weight: 0-1%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


SILICON DIOXIDE (SILICA GEL)

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: 0-2%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 0-3%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


POTASSIUM SILICATE

CAS: 1312-76-1

Fraction By Weight: 0-3%

ACGIH TLV: 5 MG/M3 (MFR)


SODIUM SILICATE

CAS: 1344-09-8

Fraction By Weight: 0-5%

ACGIH TLV: 5 MG/M3 (MFR)


CRYOLITE

CAS: 15096-52-3

RTECS: WA9625000

Fraction By Weight: 0-2%

OSHA PEL 2.5 MG/M3 (AS F)

ACGIH TLV: 2.5 MG/M3 (AS F)


MAGNESITE

CAS: 546-93-0

RTECS: OM2470000

Fraction By Weight: 0-2%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9192


POTASSIUM HYDROXIDE (SARA III)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 0-0.5%

OSHA PEL C, 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:OVEREXPOSURE TO WELDING FUMES MAY:
(ACUTE)RSLT IN DISCOMFORT SUCH AS DIZZ, NAUS, OR DRYNESS/IRRIT OF
NOSE, THROAT, EYES, TIGHTNESS IN CHEST, FEVER & ALLERGIC REACTIONS;
(CHRONIC)LEAD TO SIDEROSIS (IRO N DEPOSITS IN LUNGS) & IS BELIEVED
BY SOME INVESTIGATORS TO AFFECT PULM FUNCTION. ARC RAYS CAN INJURE
EYES & BURN SKIN.
Explanation of Carcinogenicity:CHROMIUM: IARC/NTP CLASS 1
Effects of Overexposure:SEE HEALTH HAZARDS
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:REMOVE TO FRESH AIR, OBTAIN MEDICAL ATTENTION. EMPLOY FIRST
AID TECHNIQUES RECOMMENDED BY THE AMERICAN RED CROSS.

Fire Fighting

Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WELDING ARC & SPARKS CAN IGNITE
COMBUSTIBLES & FLAMMABLES. REFER TO AMERICAN NATIONAL STANDARD
Z49.1 FOR FIRE PREVENTION DURING USE OF WELDING & ALLIED PROC.

Accidental Release

Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:USE EXHAUST SYSTEM TO CLEAR WELDING FUMES. MAKE SURE
THAT INHALED AIR DOES NOT CONTAIN FUME CONSTITUENTS ABOVE
PERMISSIBLE EXPOSURE LEVELS. TRAIN WELDER TO KEEP HEAD OUT OF
FUMES/INSULATE BODY FROM WO RK & GROUND.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRABLE FUME
RESPIRATORY OR AIR-SUPPLIED RESPIRATOR WHEN WELDING IN A CONFINED
SPACE OR WHERE LOCAL EXHAUST OR VENTILATION DOES NOT KEEP EXPOSURE
BELOW THE RECOMMENDED EXPOS URE LIMIT.
Ventilation:USE ENOUGH VENT, LOCAL EXHAUST AT THE ARC, OR BOTH, TO KEEP
FUMES & GASES FROM THE WORKER'S BRTHG ZONE & GENERAL AREA.
Protective Gloves:WELDERS GLOVES
Eye Protection:WEAR HELMET OR USE FACESHLD W/FILTR LENS
Other Protective Equipment:ARM PROTECTORS, APRONS, HATS, HELMETS,
SHOULDER PROTECTION, DARK SUBSTANTIAL CLOTHING, PROT SCREENS &
FLASH GOGGLES
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, SMOKING, OR USING SANITARY FACILITIES .
Supplemental Safety and Health
HAZ DECOMP PROD: FOR HEXAVALENT CR IS 0.05 MG/M3. FUMES MAY ALSO CNTN
FLUORIDES, OSHA PEL/ACGIH TLV FOR FLUORIDES IS 2.5 MG/M3. NOTE THAT
ALL THE ABOVE WILL RSLT IN SIGNIFICANT REDUCTION FROM 5 MG/M3 GEN
FUME LVL. GASEOUS RXN PRODS MAY INCLUDE CO & CO*2. OZONE & NITROGEN
OXIDES MAY BE FORMED BY THE RADIA FROM THE ARC.

Chemical Properties

Appearance and Odor:WELDING ELECTRODE

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE, UNLESS OTHERWISE SPECIFIED
Hazardous Decomposition Products:FUMES COULD INCLUDE OXIDES OF FE;
OXIDES OF MN, SI, CR, MO ALONG W/FLUORIDES. THE OSHA PEL & ACGIH
TLV (SEE SUPP DATA)

Disposal

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT RESIDUE, DISPOSABLE CONTAINER OR
LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
WITH FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.